This can be solved by rebooting the application or changing the metering points for Output Channels from the SETUP options. If the QL StageMix screen is switched from the Master Bank that shows the Stereo/Mono levels properly to another bank and then returned to the Master Bank via the Navigation/Meter Bridge, the level meters in the Master Bank become inactive.The following problems are found in version 8.1.1 of QL StageMix.PLEASE RESTART THE CONSOLE" might have appeared even when the console was started up normally. Solved a problem in which the message "NETWORK AUDIO MODULE FAILED.Fixed a bug in which an INTERNAL USER KEY could not be generated without - authority being set in USER LEVEL when logging in as a power user.Fixed a bug in which HA of MTX3 could not be controlled using V5.60.Reduced the issue occurring that VIRTUAL is still displayed on the DEVICE MOUNT screen for devices participating in DDM.Reduced the likelihood of an error occurring that causes the message "kernel sysdwn, operation cannot be performed.” to be displayed.*With SMPTE mode enabled in DDM, the domain is configured for SMPTE ST2110-30 clocking, enabling audio interoperability between Dante and non-Dante SMPTE devices.
#Como usar namsoccgen v5 series#
However, Dante Controller will be needed to manually change the settings of R series units that are not mounted on the console with Console ID #1. This will remove the possibility data inconsistency between the console and the mounted R series units. Therefore, after updating, it is recommended to briefly change the Latency to 1.0ms on the console with the Console ID #1, then restore the original setting again. This might occur only when the Dante Latency was set to 0.25ms or 0.5ms.
#Como usar namsoccgen v5 update#
Follow the instructions on the update guide.
#Como usar namsoccgen v5 windows#
Please use Windows 7, Windows 8.1, or Windows 10.
![como usar namsoccgen v5 como usar namsoccgen v5](http://i.ytimg.com/vi/AT0_NPh-ghs/maxresdefault.jpg)
Follow the instructions on the update guide. If updating from QL V1.61 or older, or if the message "NAME SUB CPU is old" appears after updating to V5.70, copy "QL-MD103.BIN" file in QL*_firm570/NAME SUB (* is the model number) to the root directory of the USB flash drive.This method allows you to update both the firmware and the "MQLP5_70.PGM" file together at the same time.
![como usar namsoccgen v5 como usar namsoccgen v5](https://idescargar.com/wp-content/uploads/2018/06/namso-ccgen-gold-3.png)
You can now update the Dante firmware for QL also by using the USB flash drive. You also need to update the Dante firmware.
![como usar namsoccgen v5 como usar namsoccgen v5](https://i2.wp.com/img.aapks.com/imgs/1/9/a/19a2ef296dfb9b30340e81d607f3c183_fgraphic.png)